FR
Sélectionnez votre langue
Désignation
Interrupteur de position
Modèle 1
rupture brusque
Matériau du corps de base
plastique
Classe de protection
isolation de protection II
Couple de serrage de la vis de fixation en Nm
1,4
Couple de serrage des vis de contact en Nm
0,6-0,8
Courant continu thermique en A
5
Degré de pollution
3
Entrée de câble
défonçable M20
Fréquence de commutation
5 000/h
Indice de protection
IP66/IP67
Longueur de dénudage en mm
5-6
Nombre de contacts à fermeture
1
Nombre de contacts à ouverture
2
Section de raccordement max. (mm²)
0,34-1,5
Tension de résistance aux chocs assignée Uimp en kV
4
Tension d’isolation assignée Ui en V
300
Type de raccordement
bornes à vis
Vitesse d’actionnement max. en m/s
0,5
Vitesse d’actionnement min. en mm/min
10
~ CONFLICT MINERALS 3TG status
3TG possibly contained
~ CONFLICT MINERALS procurement
DRC conflict-free
~ CP65 substance 1 cancer & reproductive toxicity
lead and lead compounds
~ CP65 substance 2 cancer
soots, tars, and mineral oils
~ PFAS free?
not yet identified
~ REACH SVHC-free?
not yet identified
~ REACh SVHC 2 name > threshold
lead possible
~ RoHS conformity
yes, exemptions not yet identified
~ TSCA 6(H) conformity
yes

Description

Product description
The position switches are used for position detection and position monitoring of moving parts on machines and systems. All position switches have forced break NC contacts in accordance with IEC 60947-5-1.
Material
Housing fibreglass reinforced plastic.
Contacts (electrical) silver.
Thrust pin plastic (Drive type B acc. to EN 50047).
Note
Complete position switch in compact design. The plastic housing is equipped with a hinged and captive housing cover. The cover can be flipped opened with a screwdriver and closed again without tools. An M20x1.5 aperture is provided to pass the cables through. The cables are connected with screw terminals.

The position switch is equipped with a thrust pin actuator. Depending on the approach situation, this can be replaced by another actuator as required.

Certificates / Standards met:
CE, cULus, CCC, EAC.
EN 60947-5-1, EN ISO 13849-1.
Technical Data
Mounting position: arbitrary.
Service life: 20 years.Mechanical life: 10,000,000 operating cycles.

NC contact forced break: acc. to EN 60947-5-1.
Forced break force: >40 N.

Conditional rated short-circuit current acc. to EN 60947-5-1: 400 A.

Utilisation category acc. to IEC/EN60947-5-1:
AC15: 240 V / 3 A.
DC13: 24 V / 3 A.
Temperature range
-30 °C to +80 °C
Pour pouvoir télécharger nos modèles CAO, vous devez d’abord connecter. Si vous n’avez pas encore créé de compte, inscrivez-vous en cliquant sur « Mon compte » (à droite de l’écran) et suivez les instructions.

Altri clienti hanno acquistato anche